What was found
FOUND FRAME CORRODED 6 INCHES BY 2 INCHES, FRAME 66 LEFT AT NUT PLATE HOLES. SPLICE AND DOUBLER REPAIR PER SRM 53-41-14 FIG 201. CORROSION LEVEL 1, TASK JA-26-53500. (M)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
FOUND FRAME CORRODED 6 INCHES BY 2 INCHES, FRAME 66 LEFT AT NUT PLATE HOLES. SPLICE AND DOUBLER REPAIR PER SRM 53-41-14 FIG 201. CORROSION LEVEL 1, TASK JA-26-53500. (M)