What was found
PIT - FOUND FLOORBEAM CORRODED 2 INCHES BY 36 INCHES, Y765 PLUS FRAME 66-70. REPLACED FLOORBEAM PER SRM 51-72-11 TYPICAL 51-40-01. CORROSION LEVEL 1, TASK JA-260-53500. (M)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
PIT - FOUND FLOORBEAM CORRODED 2 INCHES BY 36 INCHES, Y765 PLUS FRAME 66-70. REPLACED FLOORBEAM PER SRM 51-72-11 TYPICAL 51-40-01. CORROSION LEVEL 1, TASK JA-260-53500. (M)