What was found
CLT - Q2 - HORIZONTAL ANGLE, 1 INCH CRACK, STA 695 LT OF BL0. REMOVED FABRICATED AND INSTALLED NEW L ANGLE IAW DWG. (K)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
CLT - Q2 - HORIZONTAL ANGLE, 1 INCH CRACK, STA 695 LT OF BL0. REMOVED FABRICATED AND INSTALLED NEW L ANGLE IAW DWG. (K)