What was found
CLT - FOUND FLOORBEAM CORRODED 1.5 INCH BY 1.5 INCH, STATION 312 RBL 10. NEW TEE CAP INSTALLED IAW SRM 53-10-01, AND SRM 53-00-51. (M)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
CLT - FOUND FLOORBEAM CORRODED 1.5 INCH BY 1.5 INCH, STATION 312 RBL 10. NEW TEE CAP INSTALLED IAW SRM 53-10-01, AND SRM 53-00-51. (M)