What was found
CLT - FOUND FLOOR SUPPORT CORRODED 1 INCH BY 1 INCH, FORWARD CABIN FLOOR STRUCTURE STATION 310 RBL 13 TOP OF SUPPORT INBOARD SCREW HOLE. REMOVED DAMAGED STIFFENER, FRILLED UP AND INSTALLED PART IAW SRM 53-10-51 FIG 101, PAGE 105. (M)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
CLT - FOUND FLOOR SUPPORT CORRODED 1 INCH BY 1 INCH, FORWARD CABIN FLOOR STRUCTURE STATION 310 RBL 13 TOP OF SUPPORT INBOARD SCREW HOLE. REMOVED DAMAGED STIFFENER, FRILLED UP AND INSTALLED PART IAW SRM 53-10-51 FIG 101, PAGE 105. (M)