What was found
CLT - FOUND PRESSURE DECK CRACKED .750 INCH, STATION 664 LBL 32.5. REMOVED DAMAGED DAMAGED AREA, INSTALLED REPAIR IAW SRM 53-60-04. (M)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
CLT - FOUND PRESSURE DECK CRACKED .750 INCH, STATION 664 LBL 32.5. REMOVED DAMAGED DAMAGED AREA, INSTALLED REPAIR IAW SRM 53-60-04. (M)