What was found
PIT - FOUND DOOR SILL CORRODED 1 INCH, -1732 FLOORBEAM/DOORSILL AT FRAME 66. REMOVED AND REPLACED DOORSILL/FLOORBEAM PER SRM 51-72-11. CORROSION LEVEL 1, TASK JA-260-53500. (M)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
PIT - FOUND DOOR SILL CORRODED 1 INCH, -1732 FLOORBEAM/DOORSILL AT FRAME 66. REMOVED AND REPLACED DOORSILL/FLOORBEAM PER SRM 51-72-11. CORROSION LEVEL 1, TASK JA-260-53500. (M)