What was found
PIT - FOUND FLOOR SUPPORT SEAT TRACK CORRODED 2 FT BY .5 INCH, BETWEEN C18 AND C20. REPLACED BEAM SECTION PER DWG D53110900. CORROSION LEVEL 1, TASK JA-220-53500. (M)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
PIT - FOUND FLOOR SUPPORT SEAT TRACK CORRODED 2 FT BY .5 INCH, BETWEEN C18 AND C20. REPLACED BEAM SECTION PER DWG D53110900. CORROSION LEVEL 1, TASK JA-220-53500. (M)