What was found
PIT - FOUND FLOOR SUPPORT CORRODED 1 INCH DIAMETER HOLES AROUND NUT PLATES, -Y1200 BETWEEN FRAME 66/69. REPLACED 3 SECTIONS OF FLOORBEAM PER SRM 51-72-11. (M)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
PIT - FOUND FLOOR SUPPORT CORRODED 1 INCH DIAMETER HOLES AROUND NUT PLATES, -Y1200 BETWEEN FRAME 66/69. REPLACED 3 SECTIONS OF FLOORBEAM PER SRM 51-72-11. (M)