What was found
PIT - FOUND BEAM CORRODED 2 INCHES BY 1 INCH, FLOORBEAM FRAME 16, FRAME 16-Y254. REPLACED BEAM PER SRM 51-72-11. (M)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
PIT - FOUND BEAM CORRODED 2 INCHES BY 1 INCH, FLOORBEAM FRAME 16, FRAME 16-Y254. REPLACED BEAM PER SRM 51-72-11. (M)