What was found
FOUND FLOORBEAM CORRODED .040 INCH DEEP BY .5 INCH DIAMETER, 41 INCHES LT OF CENTER LINE A C16. CORROSION LEVEL 1, TASK JA-220-53500. REMOVED AND REPLACED BEAM IAW SRM 51-40-00. (M)