What was found
PIT - FOUND FLOORBEAM CORRODED 1 INCH BY 2 INCH ON EACH OF THREE BEAMS, FRAME 64-69, 50 INCHES RIGHT OF CENTER. REMOVED AND REPLACED WITH IDENTICAL PART PER SRM 51-72-11. CORROSION LEVEL 2, TASK JA-260-53500. (M)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
PIT - FOUND FLOORBEAM CORRODED 1 INCH BY 2 INCH ON EACH OF THREE BEAMS, FRAME 64-69, 50 INCHES RIGHT OF CENTER. REMOVED AND REPLACED WITH IDENTICAL PART PER SRM 51-72-11. CORROSION LEVEL 2, TASK JA-260-53500. (M)