What was found
FOUND FLOORBEAM CORRODED .5 INCH BY 1 INCH AREA, FRAME 66 RT SIDE AT DOOR CUTOUT. CORROSION LEVEL 1, TASK JA-260-53500. INSTALLED REPAIR ANGLES AND FILLER IAW SRM 53-41-14. (M)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
FOUND FLOORBEAM CORRODED .5 INCH BY 1 INCH AREA, FRAME 66 RT SIDE AT DOOR CUTOUT. CORROSION LEVEL 1, TASK JA-260-53500. INSTALLED REPAIR ANGLES AND FILLER IAW SRM 53-41-14. (M)