What was found
PIT - FOUND BEAM CORRODED 1 SQUARE INCH, FLOOR SUPPORT AT C-20 Y-254. INSTALLED REPAIR ANGLE PER SRM 53-00-14, PAGE 223/224 FIG 204. (M)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
PIT - FOUND BEAM CORRODED 1 SQUARE INCH, FLOOR SUPPORT AT C-20 Y-254. INSTALLED REPAIR ANGLE PER SRM 53-00-14, PAGE 223/224 FIG 204. (M)