What was found
PIT - FOUND BEAM CORRODED .5 INCH BY .5 INCH AND .5 INCH BY .5 INCH, ON FLOORBEAM BETWEEN FRAME 66/68 -Y450 INCH. REPLACED BEAM PER SRM 53-41-00. CORROSION LEVEL 1, TASK JA-260-53500. (M)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
PIT - FOUND BEAM CORRODED .5 INCH BY .5 INCH AND .5 INCH BY .5 INCH, ON FLOORBEAM BETWEEN FRAME 66/68 -Y450 INCH. REPLACED BEAM PER SRM 53-41-00. CORROSION LEVEL 1, TASK JA-260-53500. (M)