What was found
CLT - Q6 - LUG/BUSHING, 2 INCH DIA X .015 TYPICAL, CORROSION; NO LEVEL OR TASK, L3, AFT FACE, LT HORIZONTAL STABILIZER. REMOVED CORROSION, FABRICATED NEW BUSHING IAW SRM. (K)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.