What was found
CLT - FOUND FLOORBEAM UPPER CHORD CORRODED 1 INCH BY 1 INCH, BS 344 BETWEEN LBL 55 - RBL 13. REMOVED UPPER CHORD OF FLOORBEAM. INSTALLED NEW CHORD AND ASSOCIATED REPAIR SPLICES IAW SRM 53-10-51. (M)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
CLT - FOUND FLOORBEAM UPPER CHORD CORRODED 1 INCH BY 1 INCH, BS 344 BETWEEN LBL 55 - RBL 13. REMOVED UPPER CHORD OF FLOORBEAM. INSTALLED NEW CHORD AND ASSOCIATED REPAIR SPLICES IAW SRM 53-10-51. (M)