What was found
CLT - FOUND BEAM CORRODED 28 INCHES, T-CAP OF FLOORBEAM STATION 312, LBL 2, RBL 26. REMOVED PREVIOUS T-CAP AND REPLACED WITH NEW CAP EXTENDING SPLICES PER SRM IAW SRM 53-10-51. (M)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
CLT - FOUND BEAM CORRODED 28 INCHES, T-CAP OF FLOORBEAM STATION 312, LBL 2, RBL 26. REMOVED PREVIOUS T-CAP AND REPLACED WITH NEW CAP EXTENDING SPLICES PER SRM IAW SRM 53-10-51. (M)