What was found
PIT - S2 - FLOORBEAM, 2 INCH X 3 INCH CORROSION, LEVEL 2; TASK: JA-220-53500 20 INCH LT OF CENTER AT FRAME C-16. REMOVED AND REPLACED IAW SRM. (K)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
PIT - S2 - FLOORBEAM, 2 INCH X 3 INCH CORROSION, LEVEL 2; TASK: JA-220-53500 20 INCH LT OF CENTER AT FRAME C-16. REMOVED AND REPLACED IAW SRM. (K)