What was found
FUESLAGE STATION 344 RIGHT HAS GAP. FABRICATED SHIMS AND FILLERS AND INSTALLED PER EA 96820. DEFECT SIZE: .275 INCH GAP BETWEEN THE RIGHT CREASE BEAM INNER CHORD ANGLE AND FLOORBEAM.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
FUESLAGE STATION 344 RIGHT HAS GAP. FABRICATED SHIMS AND FILLERS AND INSTALLED PER EA 96820. DEFECT SIZE: .275 INCH GAP BETWEEN THE RIGHT CREASE BEAM INNER CHORD ANGLE AND FLOORBEAM.