What was found
BS 294.5, S-17R, CUT OUT DAMAGE, FABRICATED NEW ATTACH ANGLE AND INSTALLED IAW SRM 51-70-11 TABLE 5 OF FIG NR 1, DEFECT SIZE: .5" CRACKED DOOR FRAME.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
BS 294.5, S-17R, CUT OUT DAMAGE, FABRICATED NEW ATTACH ANGLE AND INSTALLED IAW SRM 51-70-11 TABLE 5 OF FIG NR 1, DEFECT SIZE: .5" CRACKED DOOR FRAME.