What was found
FOUND PLATE SUPPORTS CORRODED STA 1640-1681 LBL 57 WL 208.10; CORROSION LEVEL 1; TASK C53-251-03. REMOVED, FABRICATED AND INSTALLED SUPPORTS PER SRM 51-40-02, 53-60-51 FIG 101 AND 51-20-02, DEFECT SIZE: 1" BY 1" AND 1.5" BY 2".
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
FOUND PLATE SUPPORTS CORRODED STA 1640-1681 LBL 57 WL 208.10; CORROSION LEVEL 1; TASK C53-251-03. REMOVED, FABRICATED AND INSTALLED SUPPORTS PER SRM 51-40-02, 53-60-51 FIG 101 AND 51-20-02, DEFECT SIZE: 1" BY 1" AND 1.5" BY 2".