What was found
FOUND FRAME CORRODED AT STATION 867 BETWEEN S27L AND S27R. REMOVED MINOR CORROSION AND THREE FASTENERS IN THE AREA. INSTALLED NEW FASTNERS IAW SRM 53-00-07, DEFECT SIZE: .4" BY .2".
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
FOUND FRAME CORRODED AT STATION 867 BETWEEN S27L AND S27R. REMOVED MINOR CORROSION AND THREE FASTENERS IN THE AREA. INSTALLED NEW FASTNERS IAW SRM 53-00-07, DEFECT SIZE: .4" BY .2".