What was found
FOUND SLAT DISBOND, T/E WEDGE O/B END. REMOVED DAMAGE, FAB AND INSTALLED REPAIR PARTS IAW TR 57-42-04, DEFECT SIZE: 3" X 5" DISBOND.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
FOUND SLAT DISBOND, T/E WEDGE O/B END. REMOVED DAMAGE, FAB AND INSTALLED REPAIR PARTS IAW TR 57-42-04, DEFECT SIZE: 3" X 5" DISBOND.