What was found
FOUND FWD SERV DOOR CUTOUT FWD FRAME AT LOWER O/B CORNER OF FWD UPPER STOP FITTING CRACKED. TRIMMED OUT DAMAGE AREA AND FABRICATED NEW FRAME AND INSTALLED IAW SRM 51-40-02 AND SRM 51-40-03, DEFECT SIZE: 3/16" CRACK.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
FOUND FWD SERV DOOR CUTOUT FWD FRAME AT LOWER O/B CORNER OF FWD UPPER STOP FITTING CRACKED. TRIMMED OUT DAMAGE AREA AND FABRICATED NEW FRAME AND INSTALLED IAW SRM 51-40-02 AND SRM 51-40-03, DEFECT SIZE: 3/16" CRACK.