What was found
FOUND STA 328 LBL45 FWD ENTRY FLOOR SUPPORT STRUCTURE CRACKED. REPAIR, FABRICATED NEW L-ANGLE AND INSTALLED IAW SRM 51-10-02 BOEING DWR 65-45812 DEFECT SIZE: .250"
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
FOUND STA 328 LBL45 FWD ENTRY FLOOR SUPPORT STRUCTURE CRACKED. REPAIR, FABRICATED NEW L-ANGLE AND INSTALLED IAW SRM 51-10-02 BOEING DWR 65-45812 DEFECT SIZE: .250"