What was found
MAIN CABIN FLOOR BELOW FLOOR AT BS 616 LEFT SIDE CRACKED. REMOVED & REPLACED ANGLE, INSTALLED FILLER PER SRM 51-40-02 & TYP REP 53-62-01. DEFECT SIZE: .5 INCH.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
MAIN CABIN FLOOR BELOW FLOOR AT BS 616 LEFT SIDE CRACKED. REMOVED & REPLACED ANGLE, INSTALLED FILLER PER SRM 51-40-02 & TYP REP 53-62-01. DEFECT SIZE: .5 INCH.