What was found
FOUND SERVICE DOOR SILL AREA CORRODED AT STA 295 RBL 53. REMOVED AND REPLACED ZEE ANGLE; IAW SRM 51-40-02; CORROSION LEVEL 1; TASK C53-107-01 DEFECT SIZE: 4.5" BY 2.125".
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
FOUND SERVICE DOOR SILL AREA CORRODED AT STA 295 RBL 53. REMOVED AND REPLACED ZEE ANGLE; IAW SRM 51-40-02; CORROSION LEVEL 1; TASK C53-107-01 DEFECT SIZE: 4.5" BY 2.125".