FLOORBEAM AT STA 344 BL 0 TO LBL 25 CORRODED. MAJOR REPAIR, BLENDED AREA, ALODINED AND PAINTED IAW SRM 53-10-51, DEFECT SIZE: .250 INCH.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
FLOORBEAM AT STA 344 BL 0 TO LBL 25 CORRODED. MAJOR REPAIR, BLENDED AREA, ALODINED AND PAINTED IAW SRM 53-10-51, DEFECT SIZE: .250 INCH.