What was found
FOUND CORROSION STA 986.5 BELOW TO BL45. REMOVED DAMAGED FABRICATED NEW T CAP AND INSTALLED ON FLOORBEAM IAW 53-10-05, DEFECT SIZE: .5 INCH AREAS OF CORROSION AROUND CLIP NUT HOLES 38 INCHES IN LENGTH.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
FOUND CORROSION STA 986.5 BELOW TO BL45. REMOVED DAMAGED FABRICATED NEW T CAP AND INSTALLED ON FLOORBEAM IAW 53-10-05, DEFECT SIZE: .5 INCH AREAS OF CORROSION AROUND CLIP NUT HOLES 38 INCHES IN LENGTH.