What was found
FOUND FRAME CRACKED BS 727D. REMOVED DAMAGE AND INSTALLED REPAIR DOUBLER IAW TR 53-10-20C, DEFECT SIZE: FUSELAGE FRAME CRACKED AT LT PSU RAIL ATTACH BRACKET, CRACK MEASURES .65 INCHES.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
FOUND FRAME CRACKED BS 727D. REMOVED DAMAGE AND INSTALLED REPAIR DOUBLER IAW TR 53-10-20C, DEFECT SIZE: FUSELAGE FRAME CRACKED AT LT PSU RAIL ATTACH BRACKET, CRACK MEASURES .65 INCHES.