What was found
STA 615 RT SIDE I/B UPPER CORD ANGLE JUST BELOW CABIN FLOOR CRACKED. REMOVED DAMAGE, FAB & INSTALLED FILLERS & DOUBLERS IAW TR 53062-01, DEFECT SIZE: 1.5 INCH CRACK IN THE FRAME.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
STA 615 RT SIDE I/B UPPER CORD ANGLE JUST BELOW CABIN FLOOR CRACKED. REMOVED DAMAGE, FAB & INSTALLED FILLERS & DOUBLERS IAW TR 53062-01, DEFECT SIZE: 1.5 INCH CRACK IN THE FRAME.