What was found
STA 706 FRAME WEB S9L AT I/B RIVET SECURING A/C PSU SUPPORT CRACKED. REMOVED DAMAGE AND INSTALLED, FABRICATED REPAIR PARTS IAW TR 53-10-22, DEFECT SIZE: .187 INCH.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
STA 706 FRAME WEB S9L AT I/B RIVET SECURING A/C PSU SUPPORT CRACKED. REMOVED DAMAGE AND INSTALLED, FABRICATED REPAIR PARTS IAW TR 53-10-22, DEFECT SIZE: .187 INCH.