What was found
FOUND STA 1470 RBL 2, 7 AND LBL 16,7,11. CUT OUT DAMAGE SECTIONS OF STRINGER, FAB'D AND INSTALLED REPAIR ANGLES PER SRM 53-00-53, 51-70-11 AND EA, DEFECT SIZE: .250 CIRCUMFERENCE AROUND FASTENER HOLE (6 PLACES) BY .051 DEPT.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
FOUND STA 1470 RBL 2, 7 AND LBL 16,7,11. CUT OUT DAMAGE SECTIONS OF STRINGER, FAB'D AND INSTALLED REPAIR ANGLES PER SRM 53-00-53, 51-70-11 AND EA, DEFECT SIZE: .250 CIRCUMFERENCE AROUND FASTENER HOLE (6 PLACES) BY .051 DEPT.