What was found
FOUND SUPPORT ANGLE CORRODED, STA 1460 STR 27L. FAB'D SUPPORT ANGLE PER SRM 51-40-02, 51-40-05; CORROSION TASK NR C53-155-02, DEFECT SIZE: 2"L BY 1/2"W BY .020"D.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
FOUND SUPPORT ANGLE CORRODED, STA 1460 STR 27L. FAB'D SUPPORT ANGLE PER SRM 51-40-02, 51-40-05; CORROSION TASK NR C53-155-02, DEFECT SIZE: 2"L BY 1/2"W BY .020"D.