What was found
FOUND FRAME CRACKED STA 440 AT RT PSU SUPPORT RAIL. INSTALLED FILLER AND DOUBLERS IAW TR 53-10-20C, DEFECT SIZE: .250" CRACK.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
FOUND FRAME CRACKED STA 440 AT RT PSU SUPPORT RAIL. INSTALLED FILLER AND DOUBLERS IAW TR 53-10-20C, DEFECT SIZE: .250" CRACK.