What was found
FOUND PREVIOUS REPAIR I/B T/E WEDGE. DOUBLER INSTALLED IAW TR 57-42-03 DEFECT SIZE: 4" BY 4".
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
FOUND PREVIOUS REPAIR I/B T/E WEDGE. DOUBLER INSTALLED IAW TR 57-42-03 DEFECT SIZE: 4" BY 4".