What was found
STA 1240 RBL 290 INTERCOSTAL AT AFT CARGO FLOOR CORRODED. REMOVED INTERCOSTAL, WEB, ANGLES & FITTING, FABRICATED & INSTALLED PER SRM 53-00-51, 51-40-02, DEFECT SIZE: 1" X 2" X .022" WEB, 1" X 1.5" X 0.58" FTG; 1.5" X 1" X .065" AREA.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
STA 1240 RBL 290 INTERCOSTAL AT AFT CARGO FLOOR CORRODED. REMOVED INTERCOSTAL, WEB, ANGLES & FITTING, FABRICATED & INSTALLED PER SRM 53-00-51, 51-40-02, DEFECT SIZE: 1" X 2" X .022" WEB, 1" X 1.5" X 0.58" FTG; 1.5" X 1" X .065" AREA.