What was found
STRINGER 5L AT STA 907 BUTT SPLICE CRACKED. LOCATED FASTENER HOLES IN SPLICE, INSTALLED SPLICE IAW SRM 53-10-00, DEFECT SIZE: .25 INCH.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
STRINGER 5L AT STA 907 BUTT SPLICE CRACKED. LOCATED FASTENER HOLES IN SPLICE, INSTALLED SPLICE IAW SRM 53-10-00, DEFECT SIZE: .25 INCH.