What was found
STRINGER 16L SHELF AREA AFT OF BS 348.2 AT LOWER AFT ENTRY DOOR STOP CRACKED. MAJOR REPAIR IAW SRM 53-10-04 REPAIR 2, DEFECT SIZE: .25 INCH.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
STRINGER 16L SHELF AREA AFT OF BS 348.2 AT LOWER AFT ENTRY DOOR STOP CRACKED. MAJOR REPAIR IAW SRM 53-10-04 REPAIR 2, DEFECT SIZE: .25 INCH.