What was found
FOUND FLOORBEAM BS 344 LBL 45 CRACKED. REPLACED FLOORBEAM STRAP IAW SRM 51-10-02, DEFECT SIZE: .250 INCH.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
FOUND FLOORBEAM BS 344 LBL 45 CRACKED. REPLACED FLOORBEAM STRAP IAW SRM 51-10-02, DEFECT SIZE: .250 INCH.