What was found
FOUND STA 1681.8, 12 INCHES I/B OF STR 17L ON FLOOR SUPPORT AFT ANGLE CORRODED. REMOVED AND REPLACED PART PER SRM 51-30-01, 51-40-02, DWG 146N5246; CORRODED TASK JL-57-53505, LEVEL 1, DEFECT SIZE: 1 BY 8 INCH.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
FOUND STA 1681.8, 12 INCHES I/B OF STR 17L ON FLOOR SUPPORT AFT ANGLE CORRODED. REMOVED AND REPLACED PART PER SRM 51-30-01, 51-40-02, DWG 146N5246; CORRODED TASK JL-57-53505, LEVEL 1, DEFECT SIZE: 1 BY 8 INCH.