What was found
NR 1 PYLON STRUT FAIRING BEAM AT O/B FWD END CHAFED. FABRICATED SUPPORT BEAM, UPPER SPLICE, LOWER SPLICE PER SRM 51-70-11, 51-40-05, 51-20-1, 5-40-02, DEFECT SIZE: 1"L X 1"W X .050"D.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
NR 1 PYLON STRUT FAIRING BEAM AT O/B FWD END CHAFED. FABRICATED SUPPORT BEAM, UPPER SPLICE, LOWER SPLICE PER SRM 51-70-11, 51-40-05, 51-20-1, 5-40-02, DEFECT SIZE: 1"L X 1"W X .050"D.