What was found
STA 294 STR 13L ANGLE CRACKED BETWEEN RIVETS ON FWD SIDE OF STA CRACKED. INSTALLED FABRICATED TIE IAW SRM 51-10-02, DEFECT SIZE: .50 INCH.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
STA 294 STR 13L ANGLE CRACKED BETWEEN RIVETS ON FWD SIDE OF STA CRACKED. INSTALLED FABRICATED TIE IAW SRM 51-10-02, DEFECT SIZE: .50 INCH.