What was found
STA 295 UNDERNEATH FORWARD SERVICE DOOR SILL CRACKED. FABRICATED WEB REPAIR IAW SRM 51-70-13, DEFECT SIZE: .75 INCH.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
STA 295 UNDERNEATH FORWARD SERVICE DOOR SILL CRACKED. FABRICATED WEB REPAIR IAW SRM 51-70-13, DEFECT SIZE: .75 INCH.