What was found
BS 632 BETWEEN S30-31L CRACKED. DRILLED .250 IN HOLE, INSTALLED RIVET IAW SRM 53-00-01, DEFECT SIZE: .200 INCH.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
BS 632 BETWEEN S30-31L CRACKED. DRILLED .250 IN HOLE, INSTALLED RIVET IAW SRM 53-00-01, DEFECT SIZE: .200 INCH.