What was found
FOUND CORROSION FLOORBOARD SUPPORT BEAM AT FS 16, CENTER BEAM. CUT OUT CORROSION AND INSTALLED DOUBLER PER SRM 53-11-14 PG 201; CORROSION TASK JA-220-53500; LEVEL 1, DEFECT SIZE: 1/2" DIA.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
FOUND CORROSION FLOORBOARD SUPPORT BEAM AT FS 16, CENTER BEAM. CUT OUT CORROSION AND INSTALLED DOUBLER PER SRM 53-11-14 PG 201; CORROSION TASK JA-220-53500; LEVEL 1, DEFECT SIZE: 1/2" DIA.