What was found
DAMAGE FOUND AT STR 4L STA 500 + 5 CUT. CUT OUT DAMAGE, FABRICATED ANGLE AND FILLER FOR STRINGER SPLICE IAW SRM 53-00-03, DEFECT SIZE: .5 INCH.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
DAMAGE FOUND AT STR 4L STA 500 + 5 CUT. CUT OUT DAMAGE, FABRICATED ANGLE AND FILLER FOR STRINGER SPLICE IAW SRM 53-00-03, DEFECT SIZE: .5 INCH.