What was found
STATION 312 TO 344 IN FWD INTRY DOOR SILL. DEFECTIVE PART REPLACED WITH IDENTICAL PART , REPLACED ANGLE IAW SRM 51-10-02 LEVEL 1, C53-107-01. DEFECT SIZE: 4 INCH.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
STATION 312 TO 344 IN FWD INTRY DOOR SILL. DEFECTIVE PART REPLACED WITH IDENTICAL PART , REPLACED ANGLE IAW SRM 51-10-02 LEVEL 1, C53-107-01. DEFECT SIZE: 4 INCH.