What was found
INTERCOSTAL COMMON TO THE MAIN ENTRY DOOR, STA 348 S16L CRACKED. REPLACED ALUMINUM PARTS WITH STEEL PARTS, IAW SRM 53-10-04, DEFECT SIZE: .50 INCH.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
INTERCOSTAL COMMON TO THE MAIN ENTRY DOOR, STA 348 S16L CRACKED. REPLACED ALUMINUM PARTS WITH STEEL PARTS, IAW SRM 53-10-04, DEFECT SIZE: .50 INCH.